Draftstopping similar to fireblocking draftstopping is installed to prevent the movement of air within open building areas and is most often installed in crawl spaces attics and floor assemblies.
Attic draftstopping details.
If the assembly isn t concealed an open floor ceiling assembly above a basement draftstopping isn t required.
Draftstopping is also still required in the attic.
Attic draftstopping evaluation final report page 6 thus there is precedence to allow five story pedestal buildings with nfpa 13r sprinkler protection and no sprinkler protection in the attics.
Draftstopping shall be installed above and in line with sleeping unit and dwelling unit separation walls that do not extend to the underside of the roof sheathing above.
If there is no useable space above the assembly an attic or below it a crawlspace draftstopping isn t required.
If a fire rated assembly rather than draftstopping is required within concealed attic spaces the following details show approved one hour and two hour rated assemblies that may be used in the roof cavity and that may be constructed with gable end frames or trusses.
Multi unit housing projects are often draftstopped at specific intervals to prevent fire from jumping between adjacent units via a common attic space.
In combustible construction nearly all the codes specify that lumber or wood structural panels may be used for this purpose.
There are some points to be made about the draftstopping requirements.
The babcock davis draft stop door is a non rated access door designed to provide access through draft stop spaces in the attic while preventing a back draft from one section of the attic to another.
Figure 17 3 3 ul u338 1 hour rated wall bearing or non bearing with.
Draftstopping where useable space is both above below concealed space of floor ceiling assemblies concealed space not to exceed 1 000 sfon each side of draftstop approximately of equal sizes there are some points to be made about the draftstoppingrequirements.
4 4 2 fire alarm ibc section 907 2 9 sets the requirements for fire alarm systems in group r 2.
Draftstopping is used to subdivide flooring at specific intervals and in attics and crawl spaces.
Some codes include other draftstopping materials such as gypsum board cement fiber board or particleboard.
1 if there is no useable space above the assembly an attic or below it a.
This self closing and self latching access door allows for access from both sides of the door.